The 1092-F is a single-phase ignition transformer that operates at 120V input, 6000V secondary voltage, and 50/60 Hz frequency. It has a -30 to 40°C operating range, 90% operating relative humidity, and a 1/16" to 1/8" loading air gap. UL-recognized and CSA-certified.
The ignition transformer is suitable for commercial and industrial gas applications. The unit is used to provide a high-energy spark to the ignition electrode rod to light up the flame. The SC2100 testing equipment accessory is also available.
The 1092-F directly replaces Webster 612-6A7 and France 6EEGW-2.
Operating Relative Humidity | 90% |
---|---|
Amperage | 30A |
Approvals | UL-recognized and CSA-certified |
Voltage | 120V |
Frequency | 50/60 Hz |
Primary Voltage | 150VA |
Secondary Voltage | 6000V |
Secondary Short Circuit Current | 25/20 mA |
Operating Temperature Range | -30 to 40°C |
Loading Air Gap | 1/16" to 1/8" |